CPR – Automated External Defibrillators or AEDs

Automated External Defibrillator’s (or AED’s) are devices that treat the most common cause of sudden cardiac arrest by delivering a electrical shock to a persons body.

What an AED treats is an abnormal heart rhythm called Ventricular Fibrillation (or V-Fib) that causes the heart to stop circulating blood. V-Fib is a heart condition in which the heart quivers instead of mechanically pumping the blood throughout the body. The most effective treatment for V-Fib is CPR and use of a defibrillator. The longer it takes for CPR and an AED to be used, the less likely a person is to survive V-Fib. CPR should be stopped and an AED applied and used as soon as it is available.

Automated External Defibrillators are designed to allow anyone to use them regardless if they have been formally trained on their operations. AED’s accomplish this through use of voice instructions, pictures, and prompts. An AED will only deliver a shock if indicated and is safe when used correctly.

Quick Guide to Using an AED:
Open AED and Turn Unit On.
Attach AED Pads to victims bare chest.
Ensure AED Pads are attached to AED.
Follow Prompts of the AED.
Clear the Victim when Analyzing and Deliver Shocks.
Continue CPR starting with Chest Compressions for 2 minutes.
Follow AED instructions until emergency personnel arrive.

AED’s function by taking an EKG of the victims heart to analyze the electrical activity in an attempt to determine if the victim is in V-Fib or another heart rhythm. If the AED analysis indicated V-Fib a shock will be indicated and may be delivered by the rescuer and AED according to the device’s operating instructions. If the AED analysis finds any other rhythm than V-Fib a “No shock” instruction will be issued and the AED will not allow a shock to be delivered.

Pad Placement: AED pads typically go around the heart and are placed on the upper right side of the chest below the collar bone and on the lower left side below the nipple line near the armpit. The electricity delivered by an AED will travel in both directions between these two pads.

Rescuers using an AED must always listen to the instructions of an AED. The AED will advise not to touch the patient while it is analyzing the victims heart and again if a shock is indicated. If the victim is touched or moved during analysis the AED may interrupt those movements and cause a potential false positive for V-Fib. If any person is touching the victim when a shock is actually delivered, they may receive some of the shock which may cause injury or even death. If you are operating an AED verbally yell and physically look head to toe to make sure no person is touching when the victim when the AED advises not to touch the victim.

The electricity delivered by an AED during a shock stuns the heart in an attempt to stop the abnormal rhythm. Think of an AED as a TASER for the heart. It temporarily stuns it, stops what the heart is doing, and allows it to potentially recover.

An AED does NOT restart the heart or fix a “flat line” as often shown on television. A flat line represents that there is no heart electrical activity at all. A flat line usually represents clinical death as it is rare to recover from a flat line rhythm. Recognize an AED attempts to correct electrical system of the heart that is malfunction – not jump start it. If an AED recognizes a “flat line” it will indicate “No Shock Advised” and instruct you to resume CPR. Shocking a flat line will NOT benefit the patient.

If a shock is indicated and delivered, the heart may take up to 10 minutes to recover from the cardiac arrest. Therefore, immediately after delivering a shock (or a “No Shock” indication) the rescuers must resume CPR with compressions to help mechanically get the heart beating again. Effectiveness of a shock is greatly affected by how well CPR is performed immediately thereafter. Do 5 sets of 30:2 or 2 minutes of CPR. The AED will automatically stop and give instructions exactly every 2 minutes. Repeat the process of operation and perform the tasks indicated by the AED. Remember when resuming CPR after AED usage to always being CPR with chest compressions.

When a shock is delivered the victim will often convulse. You may always witness an arch of electricity travel across the victims body, smell burning hair or skin, or see smoke. This is normal as a large amount of electricity is entering the victims body. Continue with CPR and AED usage as indicated.

Once an AED is placed, never remove the pads from the victims chest or turn the AED off until instructed to by trained healthcare professionals. If the victim wakes up or recovers they may suffer from V-Fib again and require additional AED treatment.

Next: Special Considerations when using an AED.

Related First Aid & CPR Articles:


One Comment on “CPR – Automated External Defibrillators or AEDs”

You can track this conversation through its atom feed.